Product Category:  Thermal Conductivity Meter 
Standard:   
Output Properties:   
Application:   

Thermal Conductivity of Solids and Semi-Solids

TK System: Thermal conductivity of solids and semi-solids.

TK 열전도도측정기는 고상 샘플의 열전도도를 빠르고 매우 정밀하게 측정하는 시스템으로, 정상법(steady state method)은 너무 많은 시간을 필요로 하고 종래의 과도법(transient method)은 정확성이 결여되는 단점을 해소한 기기이다.

본 시스템은광범위하게 사용되는 ASTM D 5930 및 ASTM D 5334 에 부합하는 과도 라인소스법 열전도도측정기이다.


The TK thermal conductivity measuring system is designed for fast and high precision thermal conductivity testing where steady state methods are too time-consuming and conventional transient methods do not meet the accuracy requirements. The system is based on the widely-used transient

line-source method (ASTM D 5930 and ASTM D 5334).

A new analytical data evaluation method has been developed which achieves an excellent accuracy of ± 2% and does not require any reference or calibration tests. This makes your tests not just more accurate but also faster.

The application range covers solids and semi-solids, fragments, powder and even high viscous liquids. Two-phase measurements with powders and fragments are possible.

Interchangeable needle (full-space) and half-space probes make this instrument flexible for solid, semisolid, two-phase or porous samples.

The instrument is used in many areas, e.g. civil engineering, geophysics, chemical industry and food industry.

Applications:

  • Soil testing for heat transfer capability
  • Development of solids with high or low thermal conductivity
  • Food processing
  • Heat exchanger design
  • Quality control

Technical Properties:

  • Measuring of: Solids and semi-solids, powders, two-phase and purous material and high viscous fluids
  • Measuring range: 0.1 to 10 W/mK
  • Reproducibility: 1.5%
  • Accuracy: 2% (probe dependent)
  • No reference or calibration measurements required
  • Heater current precision: 0.01%
  • Measuring period: 60 sec typ. (probe dependent)
  • Automisation: up to 99 measurements unattended
  • Sample Temperature: -0 to +70°C standard, -20°C to +150°C available
  • Sample size: arbitrary shape, no upper limit, minimum size probe dependent
  • Operating temperature: 0°C to 45°C
  • Power supply: 240/120V at 50/60Hz
  • Data transfer: RS 232, analisys program requires Win95/98/NT/XP/2000

 

F5T_logo.jpg

profile
번호
 
3 Nanofluid thermal conductivity meter Lambda 1
Thermal Conductivity
Output Properties: Thermal conductivity, Cp, specific heat capacity Density Temperature
2 Nanofluid thermal conductivity meter Lambda 2
Thermal Conductivity
Output Properties: Thermal conductivity Cp, specific heat capacity Density Temperature
Selected TK-System
Thermal Conductivity
Output Properties:
Tag List

 

회사 소개

 회원이용약관

 개인정보보호정책

 이메일 무단수집 거부

 

 

 

 

 

(우)07783 서울특별시 강서구 곰달래로 208 청송평화빌딩1층(화곡동849-22)

  Phone: 02)2675-0508 (대표) A/S: 02)2675-0566 Telefax: 02)6918-6568


 Copyrightⓒ 2017 YEONJIN S-tech. Scientifics. Ltd. All Rights Reserved. Contact
administrator for more information.