			 Model 
			 | 
			
			 SDC712  
			 | 
			|||||
| 
			 Analysis Time 
			 | 
			
			 <8min 
			 | 
			
			 <8min 
			 | 
			
			  <12min 
			 | 
			
			  <15min 
			 | 
			
			 15min-25min 
			 | 
			
			 15min-25min 
			 | 
		
| 
			 Full Test Process Time 
			 | 
			
			 <10min 
			 | 
			
			 <10min 
			 | 
			
			 | 
			
			 | 
			
			 | 
			
			 | 
		
| 
			 Temperature Resolution 
			 | 
			
			 0.0001℃ 
			 | 
			
			 0.0001℃ 
			 | 
			
			 0.0001℃ 
			 | 
			
			 0.0001℃ 
			 | 
			
			 0.0001℃ 
			 | 
			
			 0.0001℃ 
			 | 
		
| 
			 Precision(RSD) (1g Benzoic Acid) 
			 | 
			
			 ≤0.05% 
			 | 
			
			 ≤0.05% 
			 | 
			
			 ≤ 0.1% 
			 | 
			
			 ≤ 0.1% 
			 | 
			
			 ≤0.15% 
			 | 
			
			 ≤0.15% 
			 | 
		
| 
			 Heat Capacity Stability (within three months) 
			 | 
			
			 ≤0.2% 
			 | 
			
			 ≤0.2%  
			 | 
			
			 ≤0.2%  
			 | 
			
			 ≤0.2%  
			 | 
			
			 ≤0.25%  
			 | 
			
			 ≤0.25%  
			 | 
		
| 
			 System Structure 
			 | 
			
			 Benchtop / Vertical 
			 | 
			
			 Benchtop/Vertical 
			 | 
			
			 Benchtop/Vertical 
			 | 
			
			 Benchtop/Vertical 
			 | 
			
			 Benchtop 
			 | 
			
			 Vertical 
			 | 
		
| 
			 Test per Hour 
			 | 
			
			 6 
			 | 
			
			 6 
			 | 
			
			 5 
			 | 
			
			 4 
			 | 
			
			 2~4 
			 | 
			
			 2~4 
			 | 
		
| 
			 Bomb volume 
			 | 
			
			 250ml 
			 | 
			
			 250ml 
			 | 
			
			 250ml 
			 | 
			
			 252ml 
			 | 
			
			 282ml 
			 | 
			
			 282ml 
			 | 
		
| 
			 Oxygen Filling 
			 | 
			
			 Fully automatic oxygen filling & releasing, fully automatic bomb raising & lowering 
			 | 
			
			 Semi-automatic / automatic 
			 | 
			
			 Semi-automatic 
			 | 
			
			 Semi-automatic 
			 | 
			
			 Semi-automatic 
			 | 
			
			 Semi-automatic 
			 | 
		
| 
			 Bomb Identity 
			 | 
			
			 Yes 
			 | 
			
			 Yes 
			 | 
			
			 Yes 
			 | 
			
			 Yes 
			 | 
			
			 No 
			 | 
			
			 No 
			 | 
		
| 
			 Energy Measurement Range 
			 | 
			
			 0~50000J 
			 | 
			
			 0~50000J 
			 | 
			
			 0~50000J 
			 | 
			
			 0~50000J 
			 | 
			
			 0~50000J 
			 | 
			
			 0~50000J 
			 | 
		
| 
			 Bucket Filling 
			 | 
			
			 Automatic 
			 | 
			
			 Automatic 
			 | 
			
			 Automatic 
			 | 
			
			 Automatic 
			 | 
			
			 Automatic 
			 | 
			
			 Automatic 
			 | 
		
| 
			 Constant Volumetric Tank with Temp Control Device 
			 | 
			
			 Bucket determine water volume automatically 
			 | 
			
			 Bucket determine water volume automatically 
			 | 
			
			 Bucket determine water volume automatically 
			 | 
			
			 Bucket determine water volume automatically 
			 | 
			
			 No 
			 | 
			
			 No 
			 | 
		
| 
			 Independent Bucket and Jacket Water System 
			 | 
			
			 Yes 
			 | 
			
			 Yes 
			 | 
			
			 Yes 
			 | 
			
			 Yes 
			 | 
			
			 No 
			 | 
			
			 No 
			 | 
		
| 
			 Stirring Method 
			 | 
			
			 Propeller 
			 | 
			
			 Propeller 
			 | 
			
			 Propeller 
			 | 
			
			 Propeller 
			 | 
			
			 Blade 
			 | 
			
			 Blade 
			 | 
		
| 
			 Power Inverter 
			 | 
			
			 No 
			 | 
			
			 No 
			 | 
			
			 No 
			 | 
			
			 No 
			 | 
			
			 No 
			 | 
			
			 No 
			 | 
		
| 
			 Reproducibility based on analysis of 1g Benzoic Acid 
			 | 
			
			 0.10% 
			 | 
			
			 0.10% 
			 | 
			
			 0.10% 
			 | 
			
			 0.10% 
			 | 
			
			 0.15% 
			 | 
			
			 0.15% 
			 | 
		
| 
			 Average Temperature Increase 
			 | 
			
			 2℃ 
			 | 
			
			 2℃ 
			 | 
			
			 2℃ 
			 | 
			
			 2℃ 
			 | 
			
			 2℃ 
			 | 
			
			 2℃ 
			 | 
		
| 
			 Temperature Measurement 
			 | 
			
			 PT1000 
			 | 
			
			 PT1000 
			 | 
			
			 PT1000 
			 | 
			
			 PT1000 
			 | 
			
			 PT1000 
			 | 
			
			 PT1000 
			 | 
		
| 
			 Working Temperatures 
			 | 
			
			 ≤32℃ 
			 | 
			
			 ≤32℃ 
			 | 
			
			 ≤32℃ 
			 | 
			
			 ≤32℃ 
			 | 
			
			 ≦32℃ 
			 | 
			
			 ≦32℃ 
			 | 
		
| 
			 Cooling method 
			 | 
			
			 Refrigerating Device 
			 | 
			
			 Refrigerating Device 
			 | 
			
			 Automatic by water circulation 
			 | 
			
			 Automatic by water circulation 
			 | 
			
			 Automatic by water circulation 
			 | 
			
			 Automatic by water circulation 
			 | 
		
| 
			 Network 
			 | 
			
			 Yes 
			 | 
			
			 Yes 
			 | 
			
			 Yes 
			 | 
			
			 Yes 
			 | 
			
			 Yes 
			 | 
			
			 Yes 
			 | 
		
| 
			 Max.Power 
			 | 
			
			 0.6KW 
			 | 
			
			 0.6KW 
			 | 
			
			 0.65kW 
			 | 
			
			 0.65kW 
			 | 
			
			 0.5kW 
			 | 
			
			 0.5kW 
			 | 
		
| 
			 Dimension 
			 | 
			
			 Main body: 440*550*460 Water tank: 390*550*440 
			 | 
			
			 Main body: 440*550*460 Water tank: 390*550*440 
			 | 
			
			 Main body: 440*550*460 Water tank: 390*550*440 
			 | 
			
			 Main body: 440*550*460 Water tank: 390*550*440 
			 | 
			
			 Main body: 600*417*908 
			 | 
			
			 Main body: 600*417*908 
			 | 
		
| 
			 Weight 
			 | 
			
			 50kg 
			 | 
			
			 50kg 
			 | 
			
			 50kg 
			 | 
			
			 50kg 
			 | 
			
			 106kg 
			 | 
			
			 106kg 
			 | 
		
| 
			 Advance Calculation 
			 | 
			
			 Yes 
			 | 
			
			 Yes 
			 | 
			
			 Yes 
			 | 
			
			 Yes 
			 | 
			
			 No 
			 | 
			
			 No 
			 | 
		
| 
			 Analysis Report 
			 | 
			
			 Yes 
			 | 
			
			 Yes 
			 | 
			
			 Yes 
			 | 
			
			 Yes 
			 | 
			
			 Yes 
			 | 
			
			 Yes 
			 | 
		
| 
			 Statistics Report 
			 | 
			
			 Yes 
			 | 
			
			 Yes 
			 | 
			
			 Yes 
			 | 
			
			 Yes 
			 | 
			
			 Yes 
			 | 
			
			 Yes 
			 | 
		
| 
			 System Monitor 
			 | 
			
			 Yes 
			 | 
			
			 Yes 
			 | 
			
			 Yes 
			 | 
			
			 Yes 
			 | 
			
			 Yes 
			 | 
			
			 Yes 
			 | 
		
Conformance with Standard: ASTM D5865, ASTM D240, ASTM D4809, ASTM E711, ASTM D5468, AS 1038.5, BS EN 15400, BIS1350, ISO 1928, ISO 9831, ISO18125
Gas Requirement: 99.5% Oxygen
Max. Bomb pressure: 20Mp
Water Requirement: Distilled Water
Power: 220VAC 50/60Hz
하기