Flow Assurance, Paraffin Deposition and Inhibitor Testing
- 
	
	Wax Flow Loop by F5 Technologie  
In pipeline simu-lation, e.g. for ana-lysing waxy crude oil for deposition pre-diction and also in testing, developing and selecting flow assurance chemicals as wax inhibitors, it is of importance to reproduce the conditions in a real pipeline. With our newly developed, zero-slip and pulsation-free pump system, our Flow Loop provides full control of these factors:
- temperature
 - pressure
 - and shear rate / Reynolds number
 
High and low viscous samples are pumped with high accuracy. Temperature controlled pump, absolutely pulsation free and no slip.
Our newly designed, zero-slip pump system provides full flow rate at all pressure and temperatures conditions, even with very low viscous samples (down to 1 mPas). So, the lab-scale approach to deposition effects and chemical efficiency becomes absolutely reliable and reproducible. And this at real lab-scale size: The complete rig fits onto your lab desk.
Besides Wax Deposition tests, our Flow Loop provides:
- Pipeline Restart tests
NEW: Now for low viscous samples (API Gravity > 20, down to 1 mPas) - Yield Strength tests
 - Wax appearance temperature (WAT) determination
 - Rheology tests
 - Asphaltene precipitation tests
 - HP capability with live crude oil injection
 - Pressurization with synthetic natural gas (SNG)
 - Live crude oil tests up to 200 bar (2900 psi)
 
High Pressure Wax Flow Loop with Live Crude Oil Injection
Adjustable parameters as flow rate and shear rate, pre-heating and cooling temperature of the test pipeline are settable in wide ranges.
Test pipeline diameter and length are also adjustable: The test pipeline  is exchanged easily by loosening two Swagelok fittings.
The test pipelines provided by F5 Technologie have a guarranteed, constant inner roughness.
Applications
- Pipeline simulation and paraffin deposition tests
 - Wax inhibitor developing and testing
 - Test under pressure with live crude oil injection
 - Pressurization with synthetic natural gas (SNG)
 - Wax appearance temperature (WAT) determination
 - Pipeline Restart tests, now also with low viscous oils (1 mPas, API > 20)
 - Yield Strength tests
 - Flow behaviour at varying pressure, temperature, shear rate, flow rate (Reynolds number), length and diameter
 
Characteristics
- test pipeline easily exchangeable
 - all internal lines temperature controlled and heated
 - 9 to 12 temperature transducers
 - complete software control by a PC
 - all measured data is stored in Excel compatible format
 - test procedures can be stored and retrieved
 
Technical Data
- Differential pressure: 5, 10 or 20 bar (72, 145 or 290 psi)
Resolution: 0.5, 1 or 2 mbar (0.007, 0.015 or 0.029 psi) - Absolute pressure: 60 bar (870 psi) 
standard, higher pressure possible - Live crude oil injection mode at 200 bar (3000 psi) system pressure
 - Pre-heating temperature: 80°C max
 - Pipeline temperature: -30°C to 80°C
standard, alternatives available - Flow rate:
0.005 to 100 cc/min
depending on pump layout
alternatives available
pulsation-free
no pump slip 
- touch-screen display
 - PC with software for data visualisation and storage (Windows 9x/2k/NT/XP/7)
 - weight: approx. 60 kg (depending on model)
 - dimension (BxHxT): approx. 120 x 65 x 60 cm (depending on model)
 - mains power: 240 VAC @ 50/60Hz or 120VAC @ 60Hz
 - power consumption: 3500 Watt max
 