CERAMICOMB-1” Reusable Dielectric Sensor

YEONJIN 2010-08-23 15:01:29 18840

 

  •     Temperature, maximum : 250 °C
  •     Frequency, mid-con mode : 0.1 Hz ~ 100 KHz
  •     Frequency, high-con mode : 0.001 Hz ~ 100 KHz
  •      No interference with the flow of material during processing.
  •      Silver-palladium electrodes embedded in an alumina substrate.

 

The Ceramicomb-1” is designed for use in presses, molds or harsh environments where a rugged, reusable dielectric sensor is desired.

 

The Ceramicomb-1inch is designed for use in presses, molds or harsh environments where a rugged, reusable dielectric sensor is desired. It may be mounted so the electrodes are flush with a platen or mold surface, insuring no interference with the flow of material during processing. The sensor is constructed with silver-palladium electrodes embedded in an alumina substrate, protected by a stainless steel sheath with a nominal 1.0 inch (2.54 cm) diameter. A thermocouple is positioned in the ceramic just below the surface to allow measurement of process temperatures. Dielectric and thermocouple signals are routed through a 10-foot (3 m) long stainless steel conduit to high temperature connectors. Sensor and cabling are rated for operation up to 250 degrees C and are suitable for R&D, QA/QC and manufacturing applications with repetitive operations.

 

       

  

Specifications


Dimensions (available with side or rear exit conduit):
Diameter, sensor head : 1.0 inch (2.54 cm) nominal
Height, sensor head : 1.0 inch (2.54 cm) nominal
Length, conduit : 10 inch (3 m) nominal

Diameter, active face : 0.69 inch (1.75 cm)
Width, electrode : 0.020 inch (0.5 mm)
Spacing, electrode : 0.020 inch (0.5 mm)

Composition:
Ceramic : Alumina
Electrodes : Silver-palladium
Sheath/conduit : Stainless steel
Cabling : Teflon

Operational:
Temperature, maximum : 250 °C
Frequency, mid-con mode : 0.1 Hz - 100 KHz
Frequency, high-con mode : 0.001 Hz - 100 KHz

Sensor Parameters:
A/D ratio : 10 cm
Base capacitance : ~20 pF - 25 pF (actual value may vary)

Thermocouple: Type J standard,
Type K available upon request

Measurement, mid-con mode:
Log Conductivity : -13 to -4 Log(siemens/cm)
Log Ion Viscosity : 1 to 13 Log(ohm-cm)
Log Loss Factor : -1 to 4
Permittivity : 1 to 102
(Not recommended for accurate measurement
of permittivity, although trends are indicative)

Measurement, high-con mode:
Log Conductivity : -10 to -1 Log(siemens/cm)
Log Ion Viscosity : 1 to 10 Log(ohm-cm)
Log Loss Factor : 1 to 6
Permittivity : Not applicable

검색 결과 5건