TSA12Gi Thermoelectric Stage for inverted microscope
-
Thermoelectric stage with gastight chamber for inverted microscope operation
-
-25°C ~ 120°C with thermoelectric heating and cooling
-
Ideally designed for samples in Petri dishes up to φ 40.5 mm or 25mm x 75mm glass microscope slides
-
Streamlined design for long duration experiments without liquid nitrogen
Description
Instec의 TSA12Gi는 inverted 광학현미경용으로 특별히 설계된 Thermo Electric (Peltier) 기반의 핫 스테이지입니다. 넓은 샘플 챔버, 간단한 온도 컨트롤, 향상된 분위기 제어, 조정 가능한 넓은 투시창 (viewing window) 및 맞춤형 베이스 플레이트가 특징입니다.
The TSA12Gi's sample chamber can accommodate 35mm petri dish specimens and glass slides up to 53mm x 78mm(optional). Dual thermoelectric modules heat and cool with electrical current only, eliminating the need for an expensive chiller or a supply of liquid nitrogen. TEC cooling is especially convenient compared to LN2 for performing long duration experiments at cold temperatures, as it simplifies the system set up, reduces operating costs, and requires much less maintenance.
Purge gas is pre-heated/cooled before entering the sample chamber for improved thermal performance. The cover lid windows are defrosted for low temperature operation, and ports are available for the user's own atmospheric sensors, e.g. CO2, humidity, etc. The viewing aperture can be a 40mm wide window or replaced with smaller windows for better thermal operation. In addition an inner lid is available for better thermal unifomty. The TSA12Gi base plate is removable and replaceable. It can be customized to fit a specific microscope stage.
TSA12Gi is an ideal solution for applications such as Cell Culture, Biology, and Thermal Microscopy for inverted microscopes.
Thermal Features
|
Temperature Control |
mK2000 with programmable precision switching PID method |
|---|---|
|
Thermal Block |
Black anodized aluminum |
|
Sample Thermal Cover |
Removable Inner sample cover with additional window |
|
Temperature Minimum |
-25°C (with 5°C frame cooling) |
|
Temperature Maximum |
90°C |
|
Temperature Sensor |
100 Ω Platinum RTD |
|
Maximum Heating Rate |
+12°C per minute at 37°C |
|
Maximum Cooling Rate |
-10°C per minute at 0°C |
|
Minimum Heating and Cooling Rate |
±0.01°C per minute |
|
Temperature Resolution |
0.01°C |
|
Temperature Stability |
±0.05°C |
|
Power Supply |
Universal power input |
|
Software |
Windows software to record and export temperature-time data |
Optical Features
|
Optical Access |
Reflection and transmission capability |
|---|---|
|
Optical Windows |
Removable and exchangeable windows permit full-spectrum transparency |
|
Minimum Objective Working Distance |
5.4 mm |
|
Minimum Condenser Working Distance |
22.8 mm |
|
Top Window |
27 mm (outer Φ), 20 mm (inner Φ) |
|
Top Viewing Angle |
±31° from normal |
|
Transmission Aperture |
12 mm diameter |
|
Bottom Window |
38.5 mm (outer Φ), 12 mm (inner Φ) |
|
Bottom Viewing Angle |
±68° from normal |
|
Window Defrost |
Integrated external window defrost |
Structural Features
|
Sample Area |
40.5 mm diameter to fit 35 mm Petri dishes |
|---|---|
|
Chamber Height |
|
|
Frame Cooling |
Integrated frame cooling via hose barb ports with optional chiller system |
|
Mounting |
Horizontal and vertical mounting capability |
|
Frame Dimensions |
159.8 mm x 109.8 mm x 39.5 mm |
|
Weight |
1000 g |
Instec's TSA12Gi is Thermo Electroc Cooler (Peltier) based thermal stage designed specifically for inverted optical microscopes. It features a large and gas tight sample chamber, simple thermal control, improved atmospheric control, wide adjustable viewing window, and customizable base plate.
This is convenient for performing long duration experiements at cold temperatures. It also simplifies the system set up and reduces operating costs. The lid allows for precision temperature control, gas purge, and atmospheric control.