HCS302GXY Heating & Cooling Stage
-
For optical thermal microscopy and spectroscopy
-
-190°C - 400°C with liquid nitrogen cooling option
-
Large 38 mm × 50 mm sample area
-
XY sample positioning
-
Sealed chamber with gas purging capability
Description
The HCS302GXY features a gas-tight sample chamber which can be gas purged to prevent condensation or to make measurements under a controlled atmosphere and at a set temperature.Top and bottom dual pane windows on the HCS302GXY stage are removable and exchangeable to meet a range of spectroscopic needs. The stage can be mounted vertically, allowing horizontal beam access to the sample chamber. An inner thermal cover is also included for work requiring ultra-high temperature stability.
The HCS302GXY is a versatile and budget-friendly option for experiments requiring atmospheric control.
Thermal Features
|
Temperature Control |
mK2000 with programmable precision switching PID method |
|---|---|
|
Sample Thermal Cover |
Removable Inner sample cover with additional window |
|
Temperature Minimum |
-190°C (with optional liquid N2 cooling) |
|
Temperature Maximum |
400°C |
|
Temperature Sensor |
100 Ω Platinum RTD |
|
Maximum Heating Rate |
+100°C per minute at 100°C |
|
Maximum Cooling Rate |
-35°C per minute at 100°C |
|
Minimum Heating and Cooling Rate |
±0.01°C per minute |
|
Temperature Resolution |
0.01°C |
|
Temperature Stability |
±0.05°C (above 25°C), ±0.1°C (below 25°C) |
|
Power supply |
Universal power input |
|
Software |
Windows software to record and export temperature-time data |
Optical Features
|
Optical access |
Reflection and transmission capability |
|---|---|
|
Optical windows |
Removable and exchangeable windows permit full-spectrum transparency |
|
Minimum Objective Working Distance |
6.2 mm |
|
Minimum Condenser Working Distance |
13 mm |
|
Top Window |
27 mm diameter |
|
Top Viewing Angle |
±60.0° from normal |
|
Transmission Aperture |
3 mm diameter |
|
Bottom Viewing Angle |
±45° from normal |
|
Window Defrost |
Integrated external window defrost |
Structural Features
|
Sample Area |
38 mm x 50 mm |
|---|---|
|
Chamber Height |
4.0 mm without removeable inner cover 2.1 mm with removeable inner cover |
|
Sample Positioning |
10 mm fine travel with Vernier XY dials for remote manipulation in sealed chambers |
|
Atmosphere Control |
Gas purging capability to control humidity, condensation, and oxidation |
|
Frame Cooling |
Integrated frame cooling with optional chiller system |
|
Mounting |
Horizontal and vertical mounting capability |
|
Frame Dimensions |
193 mm x 86 mm x 25.5 mm |
|
Weight |
1000 g |
The HCS302GXY features a gas-tight sample chamber which can be gas purged to prevent condensation or to make measurements under a controlled atmosphere and at a set temperature.Top and bottom dual pane windows on the HCS302GXY stage are removable and exchangeable to meet a range of spectroscopic needs. The stage can be mounted vertically, allowing horizontal beam access to the sample chamber. An inner thermal cover is also included for work requiring ultra-high temperature stability.
The HCS302GXY is a versatile and budget-friendly option for experiments requiring atmospheric control.