HCS121VXY Heating & Cooling Stage
-
Microscopy and spectroscopy stage
-
-190°C ~ 100°C with liquid nitrogen cooling option
-
28 mm × 30 mm sample area
-
XY sample positioning
-
Sealed chamber with vacuum capability
Thermal Features
|
Temperature Control |
mK2000 with programmable precision switching PID method |
|---|---|
|
Thermal Block |
Silver |
|
Sample Thermal Cover |
Removable Inner sample cover with additional window |
|
Temperature Minimum |
-190°C (with optional liquid N2 cooling) |
|
Temperature Maximum |
100°C |
|
Temperature Sensor |
100 Ω Platinum RTD |
|
Maximum Heating Rate |
+150°C per minute at 37°C |
|
Maximum Cooling Rate |
-60°C per minute at 100°C |
|
Minimum Heating and Cooling Rate |
±0.01°C per minute |
|
Temperature Resolution |
0.01°C |
|
Temperature Stability |
±0.05°C (above 25°C), ±0.1°C (below 25°C) |
|
Power supply |
Universal power input |
|
Software |
Windows software to record and export temperature-time data |
Optical Features
|
Temperature Control |
mK2000 with programmable precision switching PID method |
|---|---|
|
Thermal Block |
Silver |
|
Sample Thermal Cover |
Removable Inner sample cover with additional window |
|
Temperature Minimum |
-190°C (with optional liquid N2 cooling) |
|
Temperature Maximum |
100°C |
|
Temperature Sensor |
100 Ω Platinum RTD |
|
Maximum Heating Rate |
+150°C per minute at 37°C |
|
Maximum Cooling Rate |
-60°C per minute at 100°C |
|
Minimum Heating and Cooling Rate |
±0.01°C per minute |
|
Temperature Resolution |
0.01°C |
|
Temperature Stability |
±0.05°C (>25°C), ±0.1°C (<25°C) |
|
Power supply |
Universal power input |
|
Software |
Windows software to record and export temperature-time data |
Structural Features
|
Sample Area |
28 mm x 30 mm |
|---|---|
|
Chamber Height |
2.8 mm |
|
Sample Access |
Side-loading outer cover for quick sample access without refocusing instruments |
|
Sample Positioning |
10 mm fine travel with Vernier XY dials for remote manipulation in sealed chambers |
|
Atmosphere Control |
Sealed chamber with vacuum capability to control humidity, condensation, and oxidation |
|
Frame Cooling |
Integrated frame cooling via hose barb ports with optional chiller system |
|
Mounting |
Horizontal and vertical mounting capability |
|
Frame Dimensions |
153mm x 90 mm x 22 mm |
|
Weight |
1350 g light-weight aluminum body |
